hit counter script

Procedure 3 Connection Check; Procedure 3 - Toshiba Satellite R20 Maintenance Manual

Hide thumbs Also See for Satellite R20:
Table of Contents

Advertisement

2 Troubleshooting

Procedure 3

Connection Check
The wiring diagram related to the power supply is shown below:
Any of the connectors may be disconnected. Perform starting from Check 1.
Check 1
Make sure the AC adapter and the AC power cord are firmly plugged into the DC
IN jack and wall outlet. If these cables are connected correctly, go to Check 2.
Check 2
Replace the AC adapter and the AC power cord with new ones.
• If the DC IN icon does not light, go to Procedure 5.
• If the battery icon does not light, go to Check 3.
Check 3
Make sure the battery pack is installed in the computer correctly. If the battery is
properly installed and the battery icon still does not light, go to Procedure 4.
2-14
[CONFIDENTIAL]
2.3 Power Supply Troubleshooting
Satellite R20/TECRA M7 Maintenance Manual (960-572)