General
1.12 Overview of measuring cycle functions for milling technology
1.12.2
Calibrating workpiece probes
With cycle CYCLE976 a workpiece probe can be calibrated in a hole (calibration ring) or on a
surface for a particular axis and direction.
Result:
Probe switching point (trigger value), possibly an additional position deviation, active ball
diameter of probe
1.12.3
Workpiece measurement at one point
CYCLE978 permits measurement at one point of a surface.
The measuring point is approached paraxially in the active workpiece coordinate system.
Depending on the measuring variant, the result may influence the selected tool offset or zero
offset.
Workpiece measurement: Blank measurement
Result:
• Position
• Deviation
• Zero point offset
1-34
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
Measuring cycles