hit counter script
Download Print this page
ABSCO SHEDS PREMIER 15151GK Manual

ABSCO SHEDS PREMIER 15151GK Manual

1.52mw x 1.52md x 1.95mh
Hide thumbs Also See for PREMIER 15151GK:

Advertisement

Quick Links

AU: 1800 029 70 1
NZ: 0800 466 444
For construction in non-cyclonic areas
Wind rating: N2 as per AS4055-2012.
If you require a higher wind rating please contact
us: admin@absco.com.au or 1800 029 701
NOTE: This shed can be upgraded to wind
rating: C1 as per AS4055-2012 with the additional
purchase of a Cyclone Kit.
MANU FACTURED
IN AUSTRALIA
SNAPTiTE
Assembly
Absco Industries
Assembly Instruction Manual
ABSCO PREMIER SHED
MODEL: 15151GK
1.52mW x 1.52mD x 1.95mH
admin@absco.com.au
www.abscosheds.com.au
WHEN LAYING YOUR CONCRETE
SLAB, ENSURE THERE IS A
REBATED EDGE 25mm DEEP
AROUND THE PERIMETER
THIS WILL HELP WATER EGRESS
FROM THE BASE OF THE SHED
We thank you for choosing an Australian made
shed. For further assistance please visit our detailed
instructional video library at
Http://www.abscosheds.com.au/watch-videos
At ABSCO Industries we are always looking to be
number ONE, so please let us know what you think
of our instructions. Feedback makes us better.
feedback@absco.com.au
Download the Absco
ABSCO INDUSTRIES
ASSEMBLY INSTRUCTION MANUAL
Sheds Assembly App
for instructional videos
Absco Industries
Premier Shed Model: 23151GK
When laying concrete slab, ensure there
is a rebated edge 25mm deep around
the perimeter. This will help water egress
from the base of the shed.
SHED MODEL: 23151GK
Model: 15151GK
日本改定日2021/4/28
FRONT: 2.26m
SIDE:
HEIGHT: 1.95m
BOTTOM CHANNEL
REBATED EDGE
75mm WIDE REBATE
CONCRETE SLAB
21-11-2017
10/05/19
1.2
1.52m
PAGE 01
1

Advertisement

loading

Summary of Contents for ABSCO SHEDS PREMIER 15151GK

  • Page 1 ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH AU: 1800 029 70 1 admin@absco.com.au 日本改定日2021/4/28 NZ: 0800 466 444 www.abscosheds.com.au Absco Industries Premier Shed Model: 23151GK FRONT: 2.26m SIDE: 1.52m HEIGHT: 1.95m WHEN LAYING YOUR CONCRETE SLAB, ENSURE THERE IS A REBATED EDGE 25mm DEEP AROUND THE PERIMETER BOTTOM CHANNEL...
  • Page 2 ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH GENERAL INSTRUCTIONS • Before commencing any assembly, read through these instructions in detail to gain a thorough understanding of assembly methods and associated details. • Unpack the carton and carefully identify and check off all the parts against the parts described and illustrated on "COMPONENTS PACKING LIST"...
  • Page 3: Component Description

    ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH COMPONENT PACKING LIST Check off all components. COMPONENT PART COMPONENT PART CHECK CHECK DESCRIPTION DESCRIPTION STEEL SHEET 1785mm X 773mm CHANNEL L = 1513mm STEEL SHEET CHANNEL 1915mm X 773mm L = 1513mm STEEL SHEET 1915mm X 773mm...
  • Page 4 ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH COMPONENT PACKING LIST COMPONENT PART COMPONENT PART CHECK CHECK DESCRIPTION DESCRIPTION Part No. Here CHANNEL JAMB L= 783mm L = 773mm RIDGE BEAM Part No. Here JAMB L= 1120mm L = 1513mm Part No.
  • Page 5 ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH SNAPTiTE ASSEMBLY GUIDE The Snaptite Assembly System locks end channels to all roof and wall sheets without the need for tools and fasteners. To assemble each panel, the perimeter channels are secured to the top and bottom of each panel. Gently tap the channel over the SNAPTiTE lugs on the sheet, working along the sheet.
  • Page 6 ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH OVERVIEW OF ROOF COMPONENTS Absco Industries Assembly Instruction Manual Model: 15151GK 10/05/19...
  • Page 7 ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH OVERVIEW OF WALL COMPONENTS Absco Industries Assembly Instruction Manual Model: 15151GK 10/05/19...
  • Page 8: Rear Panel Assembly

    ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH REAR PANEL ASSEMBLY 1x required. Absco Industries Assembly Instruction Manual Model: 15151GK 10/05/19...
  • Page 9 ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH ROOF PANEL ASSEMBLY 2x required. Fit 81E to edge of sheet with pre- punched holes. Absco Industries Assembly Instruction Manual Model: 15151GK 10/05/19...
  • Page 10 ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH RIGHT SIDE PANEL ASSEMBLY 1x required. Trim the tip of each sheet or bend out of the way to allow channels to fit hard up to the edge of the sheet. Absco Industries Assembly Instruction Manual Model: 15151GK...
  • Page 11 ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH LEFT SIDE PANEL ASSEMBLY 1x required. Attached mullion (80A) Trim the tip of each sheet or bend out of the way to allow channels to fit hard up to the edge of the sheet.
  • Page 12: Front Panel Assembly

    ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH FRONT PANEL ASSEMBLY 1x required. Absco Industries Assembly Instruction Manual Model: 15151GK 10/05/19...
  • Page 13 ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH DOOR PANEL ASSEMBLY SINGLE DOOR 1x required. Vertical door channels are installed in the opposite orientation compared to the horizontal door channels. Long Short fl ange fl ange of of channel channel Absco Industries Assembly Instruction Manual...
  • Page 14: Door Panel Assembly

    ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH DOOR PANEL ASSEMBLY SINGLE DOOR PANEL NOTE: Nuts and bolts are also supplied and may be used instead of rivets. Use a 4mm drill bit to enlarge these holes in the jamb NOTE: The holes to fasten the padbolt hasp are not pre-punched to allow for proper alignment.
  • Page 15 ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH PANEL CONSTRUCTION NOTE: Take care to ensure that all wall panels are not upside down. The top channels of each panel are pre-punched for attaching roof sheeting. The base channels are not pre- punched.
  • Page 16 ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH INSIDE VIEW OF FIXING Secure peak brace to Move the other roof ridge beam and roof panel into position and secure peak brace to panel with one screw at ridge beam with one each end screw at each end Slide the roof panel...
  • Page 17 ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH FINAL CONSTRUCTION Bend the top and bottom flanges as shown, then hook the bottom flanges under the top channel and screw top to the ridge beam with two screws. ANCHORING OF SHED Location of 8 Bolt and Nut* concrete...
  • Page 18 ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH Absco Gable Roof Shed Notes General • 1.G This instruction manual shall be read in conjunction with other consultants drawings, specifi cations and written instructions provided by Absco and/or their representatives. •...
  • Page 19 ABSCO PREMIER SHED MODEL: 15151GK 1.52mW x 1.52mD x 1.95mH Absco Gable Roof Shed Notes Steelwork • 1.S All structural steelwork shall have a corrosion protection system applied consistent with AS/NZS 2312- 2002. • 2.S All structural steelwork detailed within this installation manual shall be minimum Grade •...
  • Page 20 1.52mW x 1.52mD x 1.95mH Australia Product Warranty Against Defects • Absco Sheds, including garden sheds, garden beds, aviaries, storage units, garages, awnings and carports are made using high quality Australian made steel. • We are pleased to advise we warrant that the steel coating will not rust, crack, fl ake peel or blister for 30 years from date of purchase, when installed within Australia.
  • Page 21 Absco Sheds Storage Guidelines • Absco Sheds are designed to be weatherproof for normal weather conditions. In the event of extreme weather conditions such as heavy rain, combined with high wind gusts, the ridge capping, sheeting joins, screw fi xings etc., may exhibit minor deformations which may allow some water entry. These areas should be checked regularly to ensure that maximum strength and protection is maintained.