hit counter script
Download Print this page
ABSCO SHEDS 15231FK Assembly Manual
Hide thumbs Also See for 15231FK:

Advertisement

Quick Links

AU: 1800 029 701
N Z: 0800 466 444
For construction in non-cyclonic areas
Wind rating: N2 as per AS4055-2012.
If you require a higher wind rating please contact
us: admin@absco.com.au or 1800 029 701
MANU FA CT URED
IN A US TR ALIA
SNAPTiTE
Assemb ly
Absco Industries
Assembly Instruction Manual
ABSCO BASIC SHED
MODEL: 15231FK
1.52mW x 2.26mD x 1.80mH
admin@absco.com.au
www.abscosheds.com.au
WHEN LAYING YOUR CONCRETE
SLAB, ENSURE THERE IS A
REBATED EDGE 25mm DEEP
AROUND THE PERIMETER
THIS WILL HELP WATER EGRESS
FROM THE BASE OF THE SHED
We thank you for choosing an Australian made
shed. For further assistance please visit our detailed
instructional video library at
Http://www.abscosheds.com.au/watch-videos
At ABSCO Industries we are always looking to be
number ONE, so please let us know what you think
of our instructions. Feedback makes us better.
feedback@absco.com.au
Download the Absco
ABSCO INDUSTRIES
ASSEMBLY INSTRUCTION MANUAL
Sheds Assembly App
for instructional videos
Absco Industries
Premier Shed Model: 23151GK
When laying concrete slab, ensure there
is a rebated edge 25mm deep around
the perimeter. This will help water egress
from the base of the shed.
SHED MODEL: 23151GK
Model: 15231FK
FRONT: 2.26m
SIDE:
HEIGHT: 1.95m
BOTTOM CHANNEL
REBATED EDGE
75mm WIDE REBATE
CONCRETE SLAB
21-11-2017
25/09/18
1.10
1.52m
PAGE 01
1

Advertisement

loading

Summary of Contents for ABSCO SHEDS 15231FK

  • Page 1 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH AU: 1800 029 701 admin@absco.com.au N Z: 0800 466 444 www.abscosheds.com.au Absco Industries Premier Shed Model: 23151GK FRONT: 2.26m SIDE: 1.52m HEIGHT: 1.95m WHEN LAYING YOUR CONCRETE SLAB, ENSURE THERE IS A...
  • Page 2 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH GENERAL INSTRUCTIONS • Before commencing any assembly, read through these instructions in detail to gain a thorough understanding of assembly methods and associated details. • Unpack the carton and carefully identify and check off all the parts against the parts described and illustrated on "COMPONENTS PACKING LIST"...
  • Page 3 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH COMPONENT PACKING LIST Check off all components. COMPONENT PART COMPONENT PART CHECK CHECK DESCRIPTION DESCRIPTION STEEL SHEET 54BL 1785mm X 773mm CHANNEL L = 1126.5mm STEEL SHEET 54BR 1785mm X 773mm CHANNEL L = 1126.5mm...
  • Page 4 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH COMPONENT PACKING LIST Check off all components. PART COMPONENT PART COMPONENT CHECK CHECK DESCRIPTION DESCRIPTION Part No. Here Part No. Here JAMB L= 1785mm JAMB L= 1120mm Part No. Here...
  • Page 5 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH SNAPTiTE ASSEMBLY GUIDE The Snaptite Assembly System locks end channels to all roof and wall sheets without the need for tools and fasteners. To assemble each panel, the perimeter channels are secured to the top and bottom of each panel.
  • Page 6 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH Guide on Joining Spliced Channels The text marked on all parts must be shown on the same side as each other JOIN>> JOIN>> <<JOIN JOIN>> Step 1. Step 2. Position the channels and the...
  • Page 7 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH PRE-ASSEMBLY OF SPLICED CHANNELS Join together 16x channel sections using 8x channel joiners (Part CSJ) NOTE: Some channels may have holes in them - You will need to redrill holes where CSJ joining channel covers them.
  • Page 8 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH OVERVIEW OF ROOF COMPONENTS Absco Industries Assembly Instruction Manual Model: 15231FK 25/09/18 1.10...
  • Page 9 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH OVERVIEW OF WALL COMPONENTS Absco Industries Assembly Instruction Manual Model: 15231FK 25/09/18 1.10...
  • Page 10: Rear Panel Assembly

    ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH REAR PANEL ASSEMBLY 1x required Absco Industries Assembly Instruction Manual Model: 15231FK 25/09/18 1.10...
  • Page 11 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH LEFT SIDE PANEL ASSEMBLY 1x required Absco Industries Assembly Instruction Manual Model: 15231FK 25/09/18 1.10...
  • Page 12 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH RIGHT SIDE PANEL ASSEMBLY 1x required Absco Industries Assembly Instruction Manual Model: 15231FK 25/09/18 1.10...
  • Page 13 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH ROOF PANEL ASSEMBLY 1x required Absco Industries Assembly Instruction Manual Model: 15231FK 25/09/18 1.10...
  • Page 14: Front Panel Assembly

    ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH FRONT PANEL ASSEMBLY 1x required Absco Industries Assembly Instruction Manual Model: 15231FK 25/09/18 1.10...
  • Page 15 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH DOOR PANEL ASSEMBLY SINGLE DOOR Vertical door channels are installed in the opposite orientation compared to the horizontal door channels. Long Short fl ange fl ange of of channel channel...
  • Page 16: Door Panel Assembly

    ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH DOOR PANEL ASSEMBLY SINGLE DOOR PANEL NOTE: Nuts and bolts are also supplied and may be used instead of rivets. Use a 4mm drill bit to enlarge these holes in the jamb NOTE: The holes to fasten the padbolt hasp are not pre-punched to allow for proper alignment.
  • Page 17 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH PANEL CONSTRUCTION NOTE: Take care to ensure that all wall panels are not upside down. The top channels of each panel are pre-punched for attaching roof sheeting. The base channels are not pre-punched.
  • Page 18 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH FINAL CONSTRUCTION ANCHORING OF SHED Location of 12 concrete anchors Bolt and Nut* M10 4.6/S Wall Sheet Steel Angle* 35 x 35 x 3 Each anchor consists of one nut, bolt, M10 dynabolt and steel angle.
  • Page 19 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH Absco Skillion Roof Shed Notes General • 1.G This instruction manual shall be read in conjunction with other consultants drawings, specifi cations and written instructions provided by Absco and/or their representatives.
  • Page 20 ABSCO BASIC SHED MODEL: 15231FK 1.52mW x 2.26mD x 1.80mH Absco Skillion Roof Shed Notes Steelwork • 1.S All structural steelwork shall have a corrosion protection system applied consistent with AS/NZS 2312- 2002. • 2.S All structural steelwork detailed within this installation manual shall be minimum Grade 550 for roll formed sections (including roof and wall sheeting) and Grade 250 for angle sections.
  • Page 21 Absco Sheds Storage Guidelines • Absco Sheds are designed to be weatherproof for normal weather conditions. In the event of extreme weather conditions such as heavy rain, combined with high wind gusts, the ridge capping, sheeting joins, screw fi xings etc., may exhibit minor deformations which may allow some water entry. These areas should be checked regularly to ensure that maximum strength and protection is maintained.
  • Page 22 Lifetime Warranty Statement This warranty against defects is given by: Absco Industries (ABN: 77 869 708 678) Address: PO Box 119 Acacia Ridge QLD 4110 Ph: 1800 029 701 Fax: 07 3344 1191 Email: admin@absco.com.au Date of issue: 19 December 2018 Details of Manufacturer’s Warranty This product comes with a Lifetime structural warranty from the date of purchase.
  • Page 23 IMPORTANT 1. Manufacturer’s Disclosure This warranty against defects shall not apply in the following situations: A) Where the product is not assembled in accordance with the instructions provided in the product kit; B) Where the product is used to store corrosive materials such as fertilizer, chlorine etc; C) The warranty does NOT cover damage caused by storms, wind, rain, snow or poor foundations;...