Island hood

Advertisement

®

INSTALLATION INSTRUCTIONS

for
ISLAND HOOD
FOR RESIDENTIAL USE ONLY
IMPORTANT: Save these instructions for the Local Electrical Inspector's use.
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.

Advertisement

Table of Contents
loading

Summary of Contents for Thermador VTR1000Q

  • Page 1: Installation Instructions

    ® INSTALLATION INSTRUCTIONS ISLAND HOOD FOR RESIDENTIAL USE ONLY IMPORTANT: Save these instructions for the Local Electrical Inspector’s use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference.
  • Page 2: Safety Warning

    SAFETY WARNING: Turn off power circuit at the service entrance and lock out panel, before wiring this unit. PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. INSTALLATION MUST COMPLY WITH ALL LOCAL CODES. IMPORTANT SAFETY INSTRUCTIONS ing, Refrigeration and Air Condi- WARNING tioning Engineers (ASHRAE), and WARNING the local code authorities.
  • Page 3 Parts included with your Island Hood: To be purchased separately: Remote Ventilator Models: Hood Canopy Assembly choose one of these units Rough-in Plate VTR1000Q - 1000 CFM, Transition – 3 speed, remote Diameter – 10", ventilator Length – 22-1/2" VTR1400Q - 1400 CFM, Width –...
  • Page 4: Typical Installation

    TYPICAL INSTALLATION To Be Connected to Remote Ventilator The Professional Island hood is designed to be in- stalled on a rigid structural framing. Follow these 12" min. 10" Transition installation steps for proper hood performance. Typi- cal installation of the Island Hood is shown in Figure 1. Filters NOTE: BECAUSE OF THE SIZE AND 15"...
  • Page 5: Step 3 Ducting Installation

    ) Run 10" round duct work from the remote ventilator NOTE: COLD WEATHER installations Model #VTR1000Q or Model #VTR1400Q (pur- should have an additional backdraft damper chase separately) to the transition (provided with installed to minimize backward cold air flow.
  • Page 6: Step 4 - Electrical Connection

    STEP 4 - ELECTRICAL CONNECTION: To Remote Ventilator Power Supply Wires SAFETY WARNING: Conduit Turn off power circuit at the service entrance and lock out panel before wiring this unit. WIRING TO THE REMOTE VENTILA- TOR: a ) Run five wires #12 AWG MIN. (black white, blue, red, and green) in 1/2"...
  • Page 7 STEP 6 - TURN THE POWER ON AND CHECK HOOD OPERATION Fig. 11 STEP 7 - INSTALL DRYWALL ON THE SOFFIT ADJUSTABLE CHIMNEY MOUNT- STRUCTURES MAY BE PURCHASED SEPARATELY IN THE FOLLOWING SIZES: Pro Island Chimney Assembly 9 to 15" PHICHIM15 Pro Island Chimney Assembly 15 to 27"...
  • Page 8 We reserve the right to change specifications or design without notice. These models are certified for use in the United States and Canada. Thermador is not responsible for products that are transported from the United States for use in other countries. Check with your local distributor or dealer.

This manual is also suitable for:

Vtr1400q

Table of Contents