PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
IMPORTANT:
INSTALLER:
OWNER:
WARNING:
AVERTISSEMENT:
IMPORTANT: LOCAL CODES VARY. INSTALLATION, ELECTRICAL CONNECTIONS
AND GROUNDING MUST COMPLY WITH ALL APPLICABLE CODES.
Check your local building codes for the proper method of
installation. In the U.S.A., if there are no applicable local codes,
this unit should be installed in accordance with the National Fuel
Gas Code #Z223.1-Current Issue, and the National Electrical
Code ANSI/NFPA No. 70 Current Issue. (In Canada, installation
must be in accordance with the CAN 1-B149.1 and .2 - Installation
Codes for Gas Burning Appliances and/ or local codes).
WARNING: If the information in this manual
is not followed exactly, a fire or explosion may
result causing property damage, personal
injury or death.
N Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
N
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
N Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
INSTALLATION INSTRUCTIONS MANUAL
30" BUILT-IN RANGES WITH COOK'N'VENT
ELECTRIC MODEL RED30V
DUAL-FUEL MODEL RDDS30V
Save these instructions for the local electrical inspector's use.
Please leave these Installation Instructions with this unit for the owner.
Please retain these instructions for future reference.
Before installing turn power OFF at the service panel. Lock service panel to prevent
power from being turned ON accidentally.
Avant l'installation, COUPER au tableau de service, et fermer a clef le tableau de service
pour empecher l'alimination d'etre allumée per hasard.
MOBILE home installation must conform with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
{formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD (Part 280)} or, when such standard is
not applicable, the Standard for Manufactured Home Installations,
ANSI A255.1 / NFPA501A, or with local codes.
AVERTISSEMENT: Si l'information dans ce
manuel n'est pas suivie exactement, un feu ou
une explosion peut résulter et causer des dégâts
matèriels et des risques d'accidents, ou la mort.
N Ne pas emmagasiner ou utiliser de l'essence
ou des autres vapeurs inflammables et liquides
aux endroits de celui-ci ou aucun autre
appareil.
N CE QUI FAIRE SI VOUS SENTEZ LE GAZ
Ne pas essayer d'allumer aucun appareil
Ne pas toucher aucun interrupteur
électrique; ne pas utiliser aucun téléphone
dans votre bâtiment.
Appeler immédiatement votre fournisseur
de gaz du téléphone d'un voisin. Suivre
l'instruction du fournisseur de gaz.
Si vous ne pouvez pas contacter votre
fournisseur, téléphoner le service des
incendies.
N
L'installation et le service doivent être
exécutés par un installateur qualifié, une agence
de service ou le fournisseur de gaz.
1
UL LISTED #157J
FILE # E521958
I

Advertisement

loading

Summary of Contents for Thermador RED30V

  • Page 1 UL LISTED #157J FILE # E521958 INSTALLATION INSTRUCTIONS MANUAL 30" BUILT-IN RANGES WITH COOK'N'VENT ELECTRIC MODEL RED30V DUAL-FUEL MODEL RDDS30V PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these instructions for the local electrical inspector’s use. INSTALLER: Please leave these Installation Instructions with this unit for the owner.
  • Page 2: Safety Warnings

    SAFETY WARNINGS ATTENTION: Pour réduire le risquie d'incendie et alfin CAUTION: To reduce risk of fire and to properly exhaust que l'air s'échappe bien, s'assurer de diriger l'air vers air, be sure to duct air outside. Do not vent exhaust air l'extérieur –...
  • Page 3: Table Of Contents

    SAFETY WARNINGS AVERTISSEMENT: L'appareil est pour la WARNING: This unit is designed as a cooking cuisson. Basé sur les considérations de sécurité, appliance. Based on safety consideration, never ne jamais utiliser le Cooktop pour chauffer une use it for warming or heating a room. chambre.
  • Page 4: Ventilation And Cabinet Considerations

    VENTILATION AND CABINET CONSIDERATIONS PREPARING CABINET Use the dimensions in Figure 2 to make the countertop NOTE: Follow all measurements precisely. If working with cutout. The cutout center line must be the same as the nonstandard cabinets, take care to alter the dimensions to center line of the space between the cabinet side walls.
  • Page 5 GAS CONNECTION (MODEL RDDS30V) Figure 4 – Gas Supply Location WARNING: Do not attempt any adjustment of the pressure regulator except conversion to propane. 4-1/8" From Cabinet Both AVERTISSEMENT: Ne pas entreprener aucun Sides ajustement du régulateur de la pression excepte la conversion à...
  • Page 6 RDDS30V 120/240 30 Amps 120/208 20 Amps • If local code requires separate ground, separate white RED30V 120/240 12.0 50 Amps wire and bare gound wire, connect white to white and 120/208 50 Amps ground bare wire separately.
  • Page 7: Electrical Connections

    ELECTRICAL CONNECTION (ALL MODELS) BLOWER ELECTRICAL CONNECTION Figure 7 – Blower Cord Connection The electrical connection of either the integral or remote blower shall be made on the right front corner of the plenum as shown in Figures 7 & 8. Based on the type of ventilation (integral or remote blower) Plenum Opening proceed with directions either 1 or 2.
  • Page 8: Installing The Ventilation

    INSTALLING THE VENTILATION INSTALLING A REMOTE BLOWER Figure 10 - Remote Blower Cutouts 9" dia. VTR600R CAUTION - For general ventilating use 10" dia only. Do not use to exhaust hazardous or VTR1000Q explosive materials and vapors. 14" 6-1/8" NOTE: Remove and discard shipping bracket (attached to 1"...
  • Page 9: Ventilation

    INSTALLING THE VENTILATION 4. The duct put into the unit inlet blower should be taped Figure 13 at the joint and the inlet collar. 5. Clearance to combustible material is 0". SAFETY WARNING: Before wiring the unit, turn off the proper circuit at the service box.
  • Page 10 VENTILATION INTEGRAL BLOWER - RIGHT OR LEFT DUCTING 4. Place blower inlet over plenum outlet ring (Figure 1. Determine blower direction and cutout in cabinet 14), temporarily supporting blower with wood blocks. as shown in Figs. 16 & 17. Remove the existing 1/4 – 20 screws from either 5.
  • Page 11 VENTILATION INTEGRAL BLOWER - REAR DUCTING 1. Determine blower direction. Blower may be rotated 4. Place blower inlet over plenum outlet ring (Figure as indicated in Figs. 18 and19 in order to miss wall studs. 14), temporarily supporting blower with wood blocks. Remove the existing 1/4 –...
  • Page 12 VENTILATION INTEGRAL BLOWER - FLOOR DUCTING 4. Place blower inlet over plenum outlet ring (Figure 1. Floor ducting with an integral blower requires ducting 14), temporarily supporting blower with wood blocks. to the left within the area shown in Figure 20. Floor 5.
  • Page 13 VENTILATION REMOTE BLOWER SYSTEM Figure 21 – Ducting Adapters The remote blower VTR1000Q, with 3-speed motor, is recommended for roof and exterior wall installations. Other remote blowers, without the 3-speed motor, are not compatible with the range ventilation system. Model RD310 Ducting adapters are available (purchased separately) to connect the plenum exhaust to standard ducts.
  • Page 14 VENTILATION DETERMINING REMOTE BLOWER DUCTS AND FITTINGS High levels of air flow provide better performance. For NOTE: You need to calculate the equivalent lengths of best results, use larger duct and keep the duct length as straight duct for each elbow or transition you use. See short as possible.
  • Page 15: Blower Duct Sizing

    BLOWER DUCT SIZING Figure 23B - Top View of 3-1/4" x 10" Adapter Figure 24 in two positions Studs Located on Bottom of Exhaust Plenum Model # RD310 Gasket 10-3/4" Plenum Adapter ➛ 3-3/8" Adapter Mounting Bracket CALCULATING CUBIC FEET PER MINUTE (C.F.M.) A.
  • Page 16 BLOWER DUCT SIZING...
  • Page 17 Model #RD310 NOTE: Fittings with model numbers stated are available through Equiv. Length included in Equiv. Length included your Thermador dealer. Chart 2 Equiv. Length = 15 Ft. in Chart 2 All other fittings are available from any ma- Model #I 40 7"...
  • Page 18: Anti-Tip Bracket Installation

    ANTI-TIP BRACKET INSTALLATION INSTALL ANTI-TIP BRACKET Two anti-tip brackets are supplied. The wall mounted anti- Figure 26 – Side View of Installed Range tip bracket shall be used when possible. An alternative floor mounted bracket is provided when rear side to side bracket must be removed to clear ducting.
  • Page 19 ANTI-TIP BRACKET INSTALLATION FLOOR MOUNTED ANTI-TIP BRACKET Figure 29 – Placement of Anti-tip Bracket to Floor (Top View) Wall Line 1 2 3 4 5 6 7 8 9 0 1 1 2 3 4 5 6 7 8 9 0 1 1 2 3 4 5 6 7 8 9 0 1 1 2 3 4 5 6 7 8 9 0 1 1 2 3 4 5 6 7 8 9 0 1...
  • Page 20 For the most detailed information, refer to installation instructions accompanying product or write Thermador indicating the model number. Thermador reserves the right to change specifications or design without notice. Some models are certified for use in Canada. Thermador is not responsible for products which are transported from the United States for use in Canada.

This manual is also suitable for:

Rdds30v