             2.3.2 Charging voltage confirmation
     
     
     
     
With respect to the
    1  Press Adjustment/operational checkout at the second page of the
Password protection,
refer to 2.1 setting of
service personnel
         
maintenance mode. 
 
 
 
 
 
 
 
 
    2  Press Charge voltage confirmation. 
With respect to positions of
the board and the test pin,
     
refer to "3.3.2 EZJ94 board /
EZJ106 board". 
After the completion of
the adjustment, the work
can be stopped before the
passing of 3 minutes by
pressing the Abort key. 
 
●This confirmation is performed in a state the IJ printer "stop" state.
● Attach the nozzle head cover for check.
●Before this confirmation, set "the speed follow-up" on the "user environment
setup" screen to "0: none".
● Be sure to perform this confirmation when performing the board exchange
(EZJ93 and EZJ94/EZJ106).
service maintenance screen. 
When the Next menu are not displayed in the maintenance work menu, set to
the service personnel maintenance mode by the password protection.
 
Adjust./oper. checkout
Excitation 
adjustment 
Auto-phase gain 
adjustment 
 
Since the voltage for the confirmation is output for 3 minutes, measure the TP12
on the EZJ 94 board / EZJ106 board using an oscilloscope and confirm that the
TP12 is in the range of DC 250 ± 15V.
Charge voltage confirmation 
  Proc. status: In progress 
  Execution takes 3 minutes. 
【Waveform of charge voltage confirmation】
  Charge voltage 
If the charge voltage cannot be checked using this function because the IJ printer
is operating, use the following values for reference:
Charge voltage for Auto-phase : Approx. 11 V
Charge voltage for printing (least significant dot):
Charge voltage for printing (most significant dot):
However, the charge voltage for printing will vary depending on the particle use
ratio and printing conditions (character height setting and character width).
Status:XXXXX 
Charge voltage 
Phase margin test 
confirmation 
Level sensor 
Heating unit 
confirmation 
confirmation 
 
Status:XXXXX 
Approx. 70 V (character height: 99; particle use ratio: 03)
Approx. 280 V (character height: 99; particle use ratio: 03)
2-7