  2.3.5 Level sensor confirmation
●The operation confirmation of level sensor in the main ink vessel is performed.
      ①Level over
      ①Insufficient ink
      ①Insufficient makeup ink
With respect to the
password protection,
refer to " 2.1 setting of
service personnel
maintenance mode" 
 
  1 Press Adjustment/operational checkout at the second page of the service
  2  Press Level sensor confirmation. 
   
  3  When pressing Back, the screen returns to the adjustment/operational
②Initial level
The operation confirmation of level sensor in the ink vessel is performed.
The operation confirmation of level sensor in the makeup ink vessel is performed.
Perform this test in a "Stop" or "Standby" state.
Maintenance menu 
System 
 environment setup 
operational checkout 
Download 
Unit information
maintenance screen. 
When the Next menu are not displayed in the maintenance work menu, set to
the service personnel maintenance mode by the password protection.
Adjust./oper. checkout
Excitation 
adjustment 
Auto-phase gain 
adjustment 
 
The level sensor operation state is displayed.
 
Level sensor confirmation
  <Main ink reservoir> 
      Too high      [ detected   undetected]
      Initial       [ detected   undetected] 
  <Ink reservoir> 
      Too low       [ detected   undetected] 
  <Makeup ink reservoir> 
      Too low       [ detected   undetected] 
Detected
: The sensor detected the level.
(The ink and the makeup ink are present.)
Not detected : The sensor did not detect the level.
(The ink and the makeup ink are not present.)
checkout screen.
Status:XXXXX
Adjustment/ 
Solenoid valve/ 
pump test 
Language change
System reset 
Status:XXXXX
Charge voltage 
Phase margin test
confirmation 
Level sensor 
Heating unit 
confirmation 
confirmation 
 
Status:XXXXX
2-12
Shut 
Manual 
down
Next 
 
menu
 
 
 
Back 
Shut 
Manual 
down
 
 
 
 
 
Back 
 
 
 
 
 
 
Back 