10.2.7
Next Data Enable Register A (NDERA)
NDERA is an 8-bit readable/writable register that enables or disables TPC output groups 1 and 0
(TP
to TP
) on a bit-by-bit basis.
7
0
Bit
NDER7
Initial value
Read/Write
R/W
If a bit is enabled for TPC output by NDERA, then when the 16-bit timer compare match event
selected in the TPC output control register (TPCR) occurs, the NDRA value is automatically
transferred to the corresponding PADR bit, updating the output value. If TPC output is disabled,
the bit value is not transferred from NDRA to PADR and the output value does not change.
NDERA is initialized to H'00 by a reset and in hardware standby mode. It is not initialized in
software standby mode.
Bits 7 to 0—Next Data Enable 7 to 0 (NDER7 to NDER0): These bits enable or disable TPC
output groups 1 and 0 (TP
Bits 7 to 0
NDER7 to NDER0
0
1
7
6
NDER6
NDER5
0
0
R/W
R/W
to TP
) on a bit-by-bit basis.
7
0
Description
TPC outputs TP
(NDR7 to NDR0 are not transferred to PA
TPC outputs TP
(NDR7 to NDR0 are transferred to PA
5
4
NDER4
NDER3
0
0
R/W
R/W
Next data enable 7 to 0
These bits enable or disable
TPC output groups 1 and 0
to TP
are disabled
7
0
to TP
are enabled
7
0
3
2
NDER2
NDER1
0
0
R/W
R/W
to PA
)
7
0
to PA
)
7
0
1
0
NDER0
0
0
R/W
(Initial value)
329