Before you begin
Hood Model
HMIB36WS
HMIB42WS
Installation Procedure
If it is not possible to vent cooking fumes and vapors to
the outside, the hood can be used in the non-vented
(recirculating) version, using the recirculating kit. Fumes
and vapors are recycled through grid.
Attach the deflector brackets to the upper horizontal
1.
support in the ceiling with 4 - 4.2 x 8 mm installation
screws.
Assemble the deflector extensions at a distance of 1"
2.
(25 mm) of the deflector brackets. Use 2 - 3.5 x
9.5 mm installation screws to hold it.
A
1" (25 mm)
6
B e f o r e y o u b e g i n
Recirculating Kit
RECHMIB
I n s t a l l a t i o n P r o c e d u r e
Parts Included
Hardware bag (1):
▯
4.2 x 8 mm installation screws (8)
▯
3.5 x 9.5 mm installation screws (2)
▯
Air deflector brackets (2)
▯
Charcoal filter (1)
▯
Air deflector (1)
▯
Assemble the air deflector with the upper horizontal
3.
support with 2 - 4.2 x 8 mm installation screws per
side.
Measure length of 8" (20.3 cm) vent needed to
4.
connect the transition to the deflector.
Note: Vent should fit up inside deflector 1" (25 mm)
minimum.
Measure from the bottom of the air deflector to the
5.
bottom of the hood outlet.
Cut the duct to the measured size.
6.
Slide the duct onto the bottom of the air deflector.
7.
Use duct tape or vent clamps to seal the deflector and
8.
the exhaust outlet from the hood.