340
For use of EL-S curve be sure to use select frequency source as multi-speed, to avoid nuisance
change of frequency during acceleration and deceleration.
Additional Analog Input Settings
Input Range Settings – The parameters in the following table adjust the input
characteristics of the analog current input. When using the inputs to command the
inverter output frequency, these parameters adjust the starting and ending ranges for
the current, as well as the output frequency range. Related characteristic diagrams are
located in "
Analog sampling setting is the value specified in .
Func.
Code
[OI] input active range start
frequency
[OI] input active range end
frequency
[OI] input active range start
current
[OI] input active range end
current
[OI] input start frequency
select
Refer to parameter to for analog voltage input.
Analog Input Settings
"A" Function
Name
The output frequency
corresponding to the analog
input range starting point,
range is 0.0 to 400.0 Hz
The output frequency
corresponding to the current
input range ending point,
range is 0.0 to 400.0 Hz
The starting point (offset) for
the current input range,
range is 0. to 100.%
The ending point (offset) for
the current input range,
range is 0. to 100.%
Two options; select codes:
Use offset ( value)
Use 0Hz
" on page 3-16.
Description
Defaults
Run
Mode
Initial data
Units
Edit
0.00
Hz
0.0
Hz
20.
%
100.
%
00