Func.
Name
Code
BRD activation level
(As DC Voltage)
BRD register
Free V/F setting, freq.1
Free V/F setting, voltage.1
Free V/F setting, freq.2
Free V/F setting, voltage.2
Free V/F setting, freq.3
Free V/F setting, voltage.3
Free V/F setting, freq.4
Free V/F setting, voltage.4
Free V/F setting, freq.5
Free V/F setting, voltage.5
Free V/F setting, freq.6
Free V/F setting, voltage.6
Free V/F setting, freq.7
Free V/F setting, voltage.7
Brake control enable
Brake Wait Time for Release
Brake Wait Time for
Acceleration
Brake Wait Time for
Stopping
Brake Wait Time for
Confirmation
Brake release freq.
Brake release current
Braking freq. setting
Deceleration overvoltage
suppression enable
Decel. overvolt. suppress
level
"b" Function
Description
If DC Voltage > b096,
the register consume. regeneration
power.
Range is:
330 to 380V (200V class)
660 to 760V (400V class)
Set the value of the register connected to
the inverter.By this setting, b090's upper
limit as the inverter hardware is
calcurated automatically.So, you can
focus the usage ratio as the connected
register.
Range is minimum connectable register
Rbmin to 600.0[Ω]
Set range, 0 ~ value of
Set range, 0 ~ 800V
Set range, value of ~
Set range, 0 ~ 800V
Set range, value of ~
Set range, 0 ~ 800V
Set range, value of ~
Set range, 0 ~ 800V
Set range, value of ~
Set range, 0 ~ 800V
Set range, value of ~
Set range, 0 ~ 800V
Set range, ~ 400
Set range, 0 ~ 800V
Two option codes:
Disable
Enable
Set range: 0.00 to 5.00 seconds.
Set range: 0.00 to 5.00 seconds.
Set range: 0.00 to 5.00 s seconds.
Set range: 0.00 to 5.00 seconds.
Set range: 0 to 400Hz
Set range: 0~200% of inverter rated
current
Set range: 0 to 400Hz
Disabled
Enabled
Enabled with accel.
DC bus voltage of suppression. Range is:
200V class330 to 395
400V class660 to 790
Ver.261
Run
Mode
Defaults
Edit
A
B
Initial data
Units
360/
720
Min.
Resistance
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
00
0.00
0.00
0.00
0.00
0.00
(rated
current)
0.00
00
380
/760
V
Ω
Hz
V
Hz
V
Hz
V
Hz
V
Hz
V
Hz
V
Hz
V
-
s
s
s
s
Hz
A
Hz
V