Thermador VCH36 Installation Instructions Manual
Thermador VCH36 Installation Instructions Manual

Thermador VCH36 Installation Instructions Manual

Cooker hood

Advertisement

Available languages

Available languages

Quick Links

VCH54 Mounting Plate
FIGURE 3
(not to scale) Top View
FIGURE 4
2. Prepare cabinet or soffit by tapping holes for mounting
filter housings. Figure 2 and Figure 3 show the top view of
the VCH36 and VCH54 respectively. Each figure shows
mounting hole locations, overall size of filter housing
mounting plate, and required clearance for the transition.
See Figure 4 for the clearance required for the PLENUM
transition in the VCH54 installation.
3. Attach transition to filter housing and seal with duct tape.
The VCH36 requires the VCHTR10 transition. The VCH54
requires the VCHTR10 and PLENUM transitions.
4. Attach filter housing to prepare cabinet/soffit surface
using wood screws provided. The installation requires two
people due to the size of the unit.
5. ELECTRICAL CONNECTIONS VCH36 for VCH54
A) Power supply must be rated for 120V, 60Hz, 15
amps (minimum).
BSH reserves the right to change specifications or design without notice. Some models are certified for use in Canada. BSH
is not responsible for products which are transported from the United States for use in Canada. Check with your local
Canadian distributor or dealer.
5060010149 Rev. A (ECO# 5V01LF) • BSH Home Appliances Corp.© 2003 • Litho in U.S.A. 09/03
FIGURE 5
Light
Power
Controller
Supply
N
G
B
75 Watt
75 Watt
Lamp
Lamp
VCH36 Wiring (VCH54 has three 75-watt lamps)
B) Remove junction box cover. Connect black wire #2 to
power supply black wire. Connect white wire #1 to power
supply white wire. Connect green ground wire to power
supply green wire. Use spring type wire nuts (BSH #189692)
supplied. (Lost or missing wire nuts should only be
replaced with: Spring type wire nuts, rated for a minimum
of (2) #18ga wires and a maximum of (4) #14ga wires, UL
& CSA rated to 600V and 302F/150). See Wiring Diagram,
Fig. 5.
C) Be sure that junction box cover is replaced properly.
D) The light switch must be UL listed general switch and is
supplied by the electical contractor.
6. For remote blower application see wiring instruction
included with the VTR600, VTR1000 & VTR1400. Note:
Blower switch CTR3Q must be installed to control remote
blower.
5551 McFadden Avenue, Huntington Beach, CA 92649 • 800/735-4328
Page 4
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
WARNING: TO RE-
DUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR IN-
L
G
JURY TO PERSONS, OB-
SERVE THE FOLLOWING:
W
CAUTION - FOR GENERAL
VENTILATING USE ONLY. DO
NOT USE TO EXHAUST
HAZARDOUS OR EXPLOSIVE
MATERIALS OR VAPORS.
A. Use this unit only in the manner intended
by the manufacturer. If you have ques-
tions, contact the manufacturer.
B. Before servicing or cleaning unit, switch
power off at service panel and lock the
service disconnecting means to prevent
power from being switched on acciden-
tally. When the service disconnecting
means cannot be locked, securely fasten
a prominent warning device, such as a
tag, to the service panel.
WARNING - TO REDUCE THE RISK
OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unattened at high
settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on low
or medium settings.
B. Always turn hood ON when cooking at high heat
or when cooking flaming foods.
C. Clean ventilating fans frequently. Grease should
not be allowed to accumulate on fan or filter.
D. Use proper pan size. Always use cookware
appropriate for the size of the surface element.

INSTALLATION INSTRUCTIONS

FOR RESIDENTIAL USE ONLY
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these instructions for the Local Electrical Inspector's use.
INSTALLER: Please leave these Installation Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
C. Installation work and electrical wiring
must be done by qualified persons in
accordance with all applicable codes &
standards, including fire-rated construc-
tion.
D. Sufficient air is needed for proper com-
bustion and exhasting of gases through
the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the
heating equipment manufacturers guide-
line and safety standards such as those
published by the National Fire Protection
Association (NFPA), the American Soci-
ety for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and
the local code authorities.
WARNING - TO REDUCE THE RISK OF IN-
JURY TO PERSONS IN THE EVENT OF A
RANGE TOP GREASE FIRE, OBSERVE THE FOL-
LOWING:
A. SMOTHER FLAMES with a close-fitting lid, cookie
sheet, or metal tray, then turn off the burner. BE
CAREFUL TO PREVENT BURNS. If the flames do
not go out immediately, EVACUATE AND CALL THE
FIRE DEPARTMENT.
B. NEVER PICK UP A FLAMING PAN - You may be
burned.
C. DO NOT USE A WATER, including wet dishcloths or
towels - a violent steam explosion will result.
D. Use an extinguisher ONLY if:
1) You have a Class ABC extinguisher, and you already
know how to operate it.
2) The fire is small and contained in the area where it
started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit.
Page 1
VCH36 OR VCH54
E. When cutting or drilling into wall or
ceiling, do not damage electrical wiring
and other hidden utilities.
F. CAUTION: To reduce risk of fire and to
properly exhast air, be sure to duct air
outside. Do not vent exhaust air into
spaces within walls, celinings, attics,
crawl spaces or garages.
G. WARNING - TO REDUCE
THE RISK OF FIRE, USE
ONLY METAL DUCT WORK.
H. Install this hood in accordance with all
requirements specified by the manufac-
turer of your cooktop/range

Advertisement

loading

Summary of Contents for Thermador VCH36

  • Page 1: Installation Instructions

    Connect white wire #1 to power JURY TO PERSONS IN THE EVENT OF A the VCH36 and VCH54 respectively. Each figure shows tally. When the service disconnecting supply white wire. Connect green ground wire to power...
  • Page 2 (maximum) reflector type light bulbs for 120 volts, 60 Hz. (not to scale) Top View The VCH36 has one built-in filter box and two lights. The 4. COLD WEATHER installations should have a backdraft VCH54 has two built-in filter boxes and three lights. For...
  • Page 3 Suivre les directives du Hottes Plenum et Island DUITS EN MÉTAL. Câblage VCH36 (VCH54 est doté de 3 ampoules de 75 W VCH36 Wiring (VCH54 has three 75-watt lamps) Pour toute question, communiquer fabricant de l’équipement de avec le fabricant.
  • Page 4 75 watts (maximum) pour 120 volts, 60 Hz. VCH36 Plaque de fixation 4. Pour les installations où il fait FROID, il faut installer un Le VCH36 a un boîtier de filtre et deux ampoules intégrés. 7-5/8 po (non à l’échelle) vue du registre à...
  • Page 5 La Figura 2 y la Figura 3 desconector de servicio para evitar Conecte el cable blanco #1 al cable blanco de la fuente de muestran la vista desde arriba del VCH36 y VCH54 SIGUIENTE: que alguien prenda el equipo alimentación.
  • Page 6 (no a escala) Vista desde Arriba aprobado por UL. Use focos tipo reflector de 75 Watt 7-5/8" (máximo) para 120 volts, 60 Hz. El VCH36 tienen una caja 7/8" Diam. 4. Para instalaciones en un CLIMA FRÍO se debe instalar un para filtro incluida y dos lámparas.

This manual is also suitable for:

Vch54